(RVV) 300/500V

Nominal cross-section

Nominal Cross

section   Area (mm²)

Core structure: Number of strands / Wire diameter

Conductor   structure:

Pieces/Diameter of   core

(mm)

Maximum outer diameter

Max. Outer Diameter

(mm)

Reference weight

Reference Weight

(kg/km)

2 × 0.75

2 × 24 / 0.20

7.2

50.0

2 × 1.0

2 × 32 / 0.20

7.5

57.8

2 × 1.5

2 × 30 / 0.25

8.6

74.7

2 × 2.5

2 × 49 / 0.25

10.6

120.0

3 × 0.75

3 × 24 / 0.20

7.6

63.1

3 × 1.0

3 × 32 / 0.20

8.0

74.0

3 × 1.5

3x30/0.25

9.4

102.0

3 × 2.5

3 × 49 / 0.25

11.4

162.0

4x0.75

4 × 24 / 0.20

8.3

78.5

4x1.0

4 × 32 / 0.20

9.0

97.2

4x1.5

4 × 30 / 0.25

10.5

133.0

4 × 2.5

4 × 49 / 0.25

12.5

204.0

5 × 0.75

5 × 24 / 0.20

9.3

96.9

5 × 1.0

5 × 32 / 0.20

9.8

115

5 × 1.5

5 × 30 / 0.25

11.6

158

5 × 2.5

5 × 49 / 0.25

13.9

249

The maximum size of RVV wire we can make is 5×25 square millimeters.   is   5×25mm².

 

Flat wire

Nominal cross-section

Nominal   cross

section area

(mm²)

Core structure, wire diameter

Structure/

Diameter

of   core (mm)

 

Maximum outer diameter

Max.Outside

diameter (mm)

Reference weight

Reference weight

(kg/km)

Maximum conductor resistance at 20℃

Max. Conductor resistance this

at   20℃ (Q/km)

Copper ( Copper )

Aluminum ( Aluminum )

Copper ( Copper )

Aluminum ( Aluminum )

2 × 0.75

2 × 1/0.97

4.6x7.1

43.7

24.5

24.5

 

2 × 1.0

2 × 1/1.13

4.8x7.4

51.0

18.1

18.1

 

2 × 1.5

2 × 1/1.38

5.3 × 8.5

65.9

12.1

12.1

 

2 × 2.5

2 × 1/1.78

6.2x10.1

95.7

64.9

7.41

12.1

2 × 4.0

2 × 7 / 0.85

6.9 × 11.5

146.0

80.7

4.61

7.41

2 × 6.0

2 × 7 / 1.04

7.8x13.0

200.0

104.0

3.08

4.61

2 × 10.0

2 × 7 / 1.35

7.9 × 13.4

323.0

177.0

1.83

3.08

3 × 0.75

3 × 1/0.97

4.6x9.6

62.6

 

24.5

 

3 × 1.0

3x1/1.13

4.8 × 10.1

74.3

 

18.1

 

3 × 1.5

3 × 1/1.38

5.3 × 11.7

95.6

 

12.1

 

3 × 2.5

3 × 1/1.78

6.2x14.0

140.0

93.9

7.41

12.1

3 × 4.0

3 × 7 / 0.85

7.1 × 16.3

220.0

123.0

4.61

7.41

3 × 6.0

3 × 7 / 1.04

7.8x18.2

295.0

153.0

3.08

4.61

3 × 10.0

3x7/1.35

9.5 × 23.0

485.0

261.0

1.83

3.08

 

Voltage Testing

Trial Name   Testing

Test item

Testing   Item

Testing value

Wire rated voltage

300/500V

450/750V

 

Voltage Test for Finished Insulated Conductor Cores

Test Voltage (V): According to Insulation Thickness

Testing Voltage: Different ten   thickness of   insulation

0.6 mm And below

0.6mm  and   below

1500

 

0.6 mm The above   Over 0.6 mm

2000

 

Minimum testing time: 5 minutes minutes

Finished Wire Voltage Test

Finished wire testing

Testing Voltage

2000

2000

Minimum testing time: 5 minutes Min. testing time: 5 minutes

Keywords